Southbend SEZ/3 Electric Steamer User Manual


 
TROUBLESHOOTING SEZ SERIES COUNTERTOP STEAMERS
PAGE 34 OPERATORS MANUAL 1183437
TROUBLESHOOTING
Figure 17
Pressure Switch Check
COM
Float Control Box
Pressure Switch
SWITCH DETAIL
NO
NC
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove rear cover.
3. Remove wires B40 and B42 from pressure switch “COM” and “NO” terminals.
4. Open door.
5. Place test leads on “COM” and “NO” terminals as shown.
6. Check continuity. There should NOT be continuity. Replace as necessary.
7. Remove pressure switch from lid.
8. With test leads on “COM” and “NO” terminals as before, gently blow into pressure port and check
continuity. There SHOULD be continuity. Replace as necessary.