Southbend SEZ/3 Electric Steamer User Manual


 
SEZ SERIES COUNTERTOP STEAMERS TROUBLESHOOTING
OPERATORS MANUAL 1183437 PAGE 35
TROUBLESHOOTING
Figure 18
High-Limit Thermostats Check
1. Note: Allow cavity bottom to cool before performing this test.
2. Disconnect left thermostat lead wire from wire B62.
3. Disconnect center thermostat lead wire from wire B57.
4. Disconnect right thermostat lead wires from wires B58 and B59.
5. Disconnect remaining thermostat lead wires from each other.
6. Test each thermostat for continuity. Replace as necessary.
7. Reconnect all thermostat lead wires.