Southbend SEZ/3 Electric Steamer User Manual


 
SEZ SERIES COUNTERTOP STEAMERS TROUBLESHOOTING
OPERATORS MANUAL 1183437 PAGE 27
TROUBLESHOOTING
Figure 10
Power Switch Continuity Check
Control Panel
Fuse Bloc
k
“ON” Light
Power Switch
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove control panel.
3. Turn Lever to “ON” from “OFF” and to “OFF” from “ON” ensuring that the power switch is properly
actuated.
4. Remove power switch lead wires from fuse block and terminal strip (note wire locations).
5. Place test leads on “C” and “NO” lead wires as shown.
6. Check for continuity with lever in “OFF” position (there should be no continuity).
7. Check for continuity with lever in “ON” position (there should be continuity).
8. Repeat steps 5 through 7 with test leads between other pair of “C” and “NO” lead wires.
9. Place test lead on “NO” lead wire and other test lead on other “NO” lead wire.
10. Check for continuity with lever in “ON” position (there should be no continuity).
11. Reconnect wires or replace switch as necessary.