A. Spigot Switch
The spigot switch will automatically actuate the
auger drive and refrigeration systems when the
spigot is opened to dispense product. When the
spigot is closed, the drive motor and compressor
will remain “on” until the product in the barrel
reaches the proper consistency.
B. Main Freezer Power OFF-ON Switch
The Main Freezer Power OFF-ON switch is a two
position toggle switch used to supply power to the
control circuit. When the switch is in the OFF
position, power will not be supplied to the control
board or refrigeration system. When the switch is
in the ON position, the freezer will operate in the
freezing mode or cleaning mode. The freezer will
be in the sleep mode until a switch is activated.
C. PUSH TO FREEZE Button
The PUSH TO FREEZE button is used to initiate
the serve mode. To start the freezer, place the
Main Freezer Power OFF-ON switch in the ON
position and press the PUSH TO FREEZE button.
NOTE
After the drive motor starts, there is a 3 second de-
lay before the compressor starts.
D. LEDs
The membrane switch features two lights; a green
LED and an amber LED. The green LED is lit
during serve mode. During freeze down, the green
LED is not lit. When product consistency
approaches 75% in the freezing cylinder, the
green LED flashes. The amber LED is lit during all
other modes. In the event of an error or when the
freezing cylinder is off, both LEDs will alternatively
flash.
NOTE
If the freezer shuts off, and alternating green and
amber lights are flashing, the freezer is in an error
condition. If the LCD displays an error, turn the Main
Freezer Power OFF-ON switch to the OFF posi-
tion, correct the problem (Refer to Troubleshooting
in Section 4) and turn the freezer back on.
E. CLEAN Button
The CLEAN button will stop all refrigeration and
start auger rotation. A CLEAN message will display
on the LCD screen and a 5 minute timer begins.
To exit the CLEAN mode, press the CLEAN
button again. If the freezer is left in CLEAN for
more than 20 minutes, it will go into an error to
prevent damage to the freezing cylinder. When
this error occurs, refrigeration will start to prevent
mix spoilage. To reset, place the Main Freezer
Power OFF-ON switch in the OFF position and
back in the ON position.
F. Mix Low Light Indicator
The MIX LOW message will appear on the LCD
display to alert the operator to a low mix condition.
The message will display when there is
approximately one gallon of mix left in the hopper.
When the MIX LOW message is displayed, refill
hopper immediately.
NOTE
Failure to refill hopper immediately may result in
operational problems.
G. DISPENSE RATE ADJUSTERS
The dispense rate adjuster limits the opening of
the spigot. To adjust product dispense rate, turn
the adjusting knob clockwise for slower flow and
counterclockwise for faster flow. It takes at least
five complete turns of the adjusting knob to make
a noticeable difference in the dispense rate.
H. FRONT DOOR SAFETY SWITCH
The front door safety switch prevents the auger
from turning when the front door is removed. The
switch is open when the door is not in place and
closed when the door is properly installed.