Stoelting O111 Freezer User Manual


 
15
C. Press the up arrow button (×) until the desired
consistency setting is displayed. The higher the
number, the greater the product consistency
(firmness). When the digit reaches 9, pressing
the up arrow button (×) again will change the
value to 0. Press SET to save the value. The 0
setting cannot be set.
D. Press the SET button once to save the setting
change and return to the current mode display.
3.16 LOCKING OUT CONTROL PANEL
The IntelliTec control has a tamper proof mode to prevent
unauthorized use. When set, all buttons on the control
panel are disabled. To lock out the control panel:
A. Press and hold the PUSH TO FREEZE button for
5 seconds.
B. While still holding the PUSH TO FREEZE button,
press the CLEAN button once.
Figure 3-13 Product Consistency Control
Fine Adj
1-9 5
Figure 3-14 Locked Control Display (In Serve Mode)
SERVE
*
C. Release both buttons. An asterisk (*) will appear
after the word MODE on the display, indicating
that the control is in the lock out mode (Fig. 3-13).
D. To unlock the control panel, repeat steps A, B and
C.