Stoelting O111 Freezer User Manual


 
18
Error Code 5 - Freezing Cylinder Sensor
The Freezing Cylinder Sensor Error (E5) indicates
a failure of the barrel sensor or an extreme out of
range condition (< -34°F or > 99°F). If the control
panel displays an E5, place the Freezing Cylinder
Off-On switch in the Off position and back in the
On position. If the error persists, contact your
Authorized Stoelting Distributor for further
assistance.
NOTE
When the freezer encounters a Freezing Cylinder
Sensor Error, the freezer will continue to run using
preset timers. This mode will allow the operator to
continue serving product until the freezer can be
serviced.
Error Code 6 - Hopper Sensor (single hopper freezers)
The Hopper Sensor Error (E6) indicates a failure
of the hopper sensor or an extreme out of range
condition (< -34°F or > 99°F). If the control panel
displays an E6, place the Freezing Cylinder Off-
On switch in the Off position and back in the On
position. If the error persists, contact your
Authorized Stoelting Distributor for further
assistance.
Error Code 7 - Drive Motor
If the control panel displays a Drive Motor Error
(E7), the control does not sense current coming
from the drive motor. Place the Freezing Cylinder
Off-On switch in the Off position and back in the
On position. If the error persists, contact your
Authorized Stoelting Distributor for further
assistance.
Error Code 8 - Cab Sensor
A Cab Sensor Error (E8) will not occur on the
E111 or F111 freezer.
Error Code 9 - High Pressure Cutout
High Pressure Cutout Errors (E9) are usually
caused by a dirty or inefficient condenser. If the
control panel displays an E9 on an air cooled
freezer, check for proper air clearance around the
freezer. If the error persists, contact your
Authorized Stoelting Distributor for further
assistance.
Error Code 10 - Auxiliary Sensor
An Auxiliary Temperature Sensor Error (R10)
occurs if the temperature sensor on the control
board fails. Place the Freezing Cylinder Off-On
switch in the Off position and back in the On
position. If the error persists, contact your
Authorized Stoelting Distributor for further
assistance.
Error Code 11 - Low Temperature
The Low Temperature Error (E11) occurs when
the temperature of the gas refrigerant at the barrel
sensor falls below -20°F or -34°F (depending on
model). Although the freezer will not shut down,
the active freezing cycle will immediately end.
This error usually occurs when the freezer
continues to run in a low mix condition or if the
freezer runs out of mix. The product towards the
front of the barrel tends to freeze solid. When the
temperature on the freezing cylinder lowers to the
preset value, the IntelliTec control will display an
E11.
ALTERNATING FLASHING CONTROL PANEL LIGHTS
The display panel lights will flash in an alternating
sequence under any error codes. Clear the error
and place the Freezing Cylinder Off-On switch in
the Off position and back in the On position.