• Press and hold for 3 seconds the
‘DESCALE’ button, the ‘DESCALE’
indicator changes from a flashing light to
a constant light. The descaling programme
is now ready and the process should not be
interrupted. See figure 61.
Note: Before the automatic process starts you
must descale the steam/hot water nozzle.
• Place a container under the steam/hot
water nozzle. The container should hold
at least 200mL. Turn the steam/hot water
switch up. Leave the switch up until
the pump switches off and no descaling
solution emerges from the nozzle. See
figure 62.
• Turn the steam/hot water switch to the
‘off’ position and the automatic descaling
process of the brewing unit starts. See
figure 63.
Note: The ‘DESCALE’ indicator remains
illuminated during the descaling process.
The programme is carried out in 2 phases;
phase 1 descaling phase with 12 cycles as
well as phase 2 rinsing phase. Between the
two phases, the coffee waste container must
be emptied and the water reservoir must be
refilled with water. In case of power failure
the programme has to be restarted.
34
Starting the descaling programme (continued)
Figure 59
Figure 60
Figure 61
Figure 62