Taylor 104 Freezer User Manual


 
19
Model 104 Operating Procedures
Step 4
Put the control switch into the OFF position. Holding a
mix pail beneath the ejection port, open the draw arm
and drain the water from the freezing cylinder . Close
the draw arm.
Repeat these procedures until the rinse water being
drawn from the freezing cylinder is clear.
Cleaning
Step 1
Prepare two quarts (1.9 liters) of an approved c leaning
solution (example: Kay--5R or Stera--S heenR). USE
W ARM WATER AND FOLLOW THE MANUF AC-
TURER’S SPECI FICATIONS.
Step 2
Pour the cleaning solution into the funnel and allow it
to flow into the freezing cylinder .
Step 3
Put the control switch into the EJECT position. This will
cause the cleaning solution in the freezing cylinder to
be agitated. Allow it to agitate for five minutes.
KEEP FINGERS OUT OF FILL AND
DISCHARGE OPENINGS! Failure to do s o may result
in personal injury or component damage.
Step 4
Put the control switch into the OFF position. Holding a
mix pail beneath the ejection port, open the draw arm
and drain all the solution from the freezing cylinder.
Close the draw arm.
Disassembly
Step 1
BE SURE THE CONTROL SWITCH IS IN
THE OFF POSITION. Failure to do so may cause
personal injury or component damage.
Step 2
Remove the handscrews from the front of the freezer
door.
Remove the pivot pin from the hinge on the freezer
door. Then remove the freezer door, beater assembly,
scraper blades, and the drive shaft from the freezing
cylinder.
Step 3
Remove the funnel from the top of the freezer and the
rear drip pan from the front panel.
Note: If the drip pan is filled with an excessive amount
of mix, it is an indication that the seal was installed
incorrectly on the beater as sembly or should be
replaced.
Brush Cleaning
Step 1
Prepare a sink with an approved cleaning solution (ex-
ample: Kay--5R or Stera--SheenR). USE WARM
W ATER AND FOLLOW THE MANUF ACTURER’S
SPECIFICATIONS.
If an approved cleaner other than Kay--5R or
Stera--SheenR is used, dilute according to label
instructions. IMPORTANT: Follow label directions, as
too STRONG of a solution can cause parts damage,
while too MILD of a solution will not provide adequate
cleaning. Make sure all brushes provided with the
freezer are available for brush cleaning.
Step 2
Remove the seal from the drive shaft.
Step 3
From the freezer door, remove the clevis pin from the
stem cap, unscrew the stem cap from the stem, pull
the draw arm from the stem, remove the o--ring from
the draw p late, remove the o--ring from the back of the
freezer door, and remove the drip spout, Take these
parts to the sink for cleaning.