Taylor Model 161 Frozen Dessert Maker User Manual


 
17
Model 161 Operating Procedures
Step 3
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, the mix inlet hole, and the
feed tube.
Figure 21
Figure 22
Step 4
Place the power switch in the ON position.
Figure 23
Step 5
Press the W ASH key. This will cause the sanitizing
solution in the freezing cylinder to be agitated. Allow it
to agitate for five minutes.
Figure 24
Step 6
Place an empty pail beneath the door spouts.
Momentarily open the center draw valve to sanitizethe
center door spout. Open the remaining draw valves to
remove all of the sanitizing solution. When the
sanitizer stops flowing from the door spouts, close the
draw valves. Press the WASH key to cancel the WASH
mode.
Step 7
With sanitized hands, stand the feed tube in the corner
of the mix hopper.
Figure 25
Repeat Steps 1 through 7 for the other side of the
machine.