6
Safety Model 430 Torque
130930
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.
S DO NOT allow untrained personnel to operate
this machine.
S DO NOT operate the freezer unless all service
panels and access doors are restrained with
screws.
S DO NOT remove any internal operating parts
(examples: freezer door, beater , scraper
blades, etc.) unless all control switches are i n
the OFF position.
Failure to follow these instructions may result i nsevere
personal injury to fingers or hands from hazardous
moving parts.
This unit has many sharp edges that can
cause severe injuries.
S DO NOT put objects or fingers in the door
spout. This may contaminate the product and
cause severe personal injury from blade
contact.
S USE EXTREME CAUTION when removing
the beater asssembly. The scraper blades are
very sharp.
This freezer must be placed on a level
surface. Failure to comply may result in personal injury
or equipment damage.
Access to the service area of the unit must be
restricted to persons having knowledge and practical
experience with the unit, in particular as far as safety
and hygiene are concerned.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to clean this unit.
This machine is designed to maintain product
temperature under 41_F(5_C). Any product being
added to this machine must be below 41_F(5_C).
Failure to follow this instruction may result in health
hazards and poor freezer performance.
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76.2 mm) of
clearance around all sides of the freezer to allow for
adequate air flow across condenser. Failure to allow
adequate clearance can reduce the refrigeration
capacity o f the freezer and possibly cause permanent
damage to the compressor.
For Indoor Use Only: This unit i s designed to operate
indoors, under normal ambient temperatures of 70_ -
75_F(21_ -24_C). The freezer has successfully
performed in high ambient temperatures of
104_(40_C) at reduced capacities.
DO NOT run the unit without product. Failure to follow
this instruction can result in damage to the unit.
NOISE L EVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor.