Taylor model 430 torque shake/slush freezer Refrigerator User Manual


 
Model 430 Torque
050367-12
08/14
Taylor Company
2014 Carrier Commercial Refrigeration, Inc.
c
W1
MIX OUT SENSITIVITY: REMOVE JUMPER TO
REDUCE SENSITIVITY.
YES
W2
MIX LOW SENSITIVITY: REMOVE JUMPER TO
REDUCE SENSITIVITY.
YES
GRN/YEL
WHT
BLK
BLK
BLK BLK
GROUND FRAME SECURELY
M
T2
COMPRESSOR
L2L1 T1
COMPRESSOR
CONTACTOR
CONDENSER
FAN MOTOR
BEATER
MOTOR
OVERLOAD
SWITCH
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
(SEE FIG 1)
BLK
BLK
COMPRESSOR
CONTACTOR
BLK WHT WHT
M
BLK BLK
WHT
WHT
L1
L1
N
AUTO
WASH
OFF
AUTO
WASH
OFF
BLK
POWER
SWITCH
BLK BLK BLU
M
BEATER
MOTOR
L2L1
BEATER MOTOR
STARTER
(SEE FIG 2)
BLK
BEATER MOTOR
STARTER
BLK WHT WHT
ONE SIDE OF A
TWO WIRE CORD
ONE SIDE OF A
TWO WIRE CORD
T1 T2
BLK
GRN/YEL
MIX
LOW
PROBE
WHT/BLU
MIX
OUT
PROBE
RED/BLK
BLK/WHT
ORG
WHT
NO
NC
DRAW
SWITCH
C0M
WHTWHTWHTORG
BEATER MOTOR
STARTER COIL
BRN/WHT WHT WHT
COMPRESSOR
CONTACTOR COIL
ADD MIX
LAMP
CLEAN REQ'D
LAMP(OPTIONAL)
ORG/WHT
BLU/WHT
WHT
WHT
WHT
NOTE:
STATIC ELECTRICITY MAY CAUSE DAMAGE TO SOLID
STATE COMPONENTS. ELIMINATE STATIC ELECTRICITY
BY TOUCHING GROUNDED UNIT BEFORE HANDLING SOLID
STATE COMPONENTS.
BLK L1
WHT NEUTRAL
LINE
5 2
4 1
RELAY
START
CAPACITOR
RUN
CAPACITOR
WHT
R
BLK
BRN
BLK
BLU
BLEED RESISTOR
BRN
S
TECUMSEH COMPRESSOR CONNECTION SCHEMATIC
BLKBLK
C
COMPRESSOR
OVERLOAD
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
1
4
5
6
BLK L1
WHT NEUTRAL
LINE
YEL/BLK
RED
BLU
YEL
BLK
MAGNETEK BEATER MOTOR CONNECTION SCHEMATIC
COUNTER CLOCKWISE ROTATION
FACING LEAD END
WHT
BLK/WHT BLK/WHT
BLK
GRN/YEL
95 96
L2 BTRCOMP
NO
C
NO
C
1 2 3 4 5 6 7 8
J3
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
ORG
NO
NC
TORQUE
SWITCH
C0M
GRN/YEL
WHT
CORCOM
FILTER
(SPINNER)
CORCOM
FILTER
MIX OUT
LAMP
WHT
RED/WHT
J1
J5
NO
NC
DOOR
SWITCH
(OPTIONAL)
C0M
FIG.1
FIG.2
BRN/WHT
BLK/WHT
YEL
WHT/BLK
BRN
WHT/RED
M
NC
NO
SPINNER
SWITCH
C0M
WHTWHTWHT
BLK
BLK
SPINNER
GRAY/WHT
GRAY
WHT/ORN
WHT
BLU
BLK
BLK
BLU
RED
240V
24VAC
AGITATOR
TRANSFORMER
M
WHT
WHT
AGITATOR
MOTOR
AGITATOR
RUN CAPACITOR
AGITATOR-OPTION
BLK
READY LAMP
(OPTIONAL)
PRP/WHT
6
1
2
J2
115V
240V
SET SWITCH
TO 115V
A2
A1
WHT/PRP
- +
NO
NC
DRAW
SWITCH
C0M
PANEL
JACK
ADDITIONAL DRAW SWITCH
OPTIONAL FOR FLAVORBURST
T1 OR BLU
T8 OR RED
THERMAL OL
BRN
BLK L1
WHT NEUTRAL
4
2
T4 OR YEL
T5 OR BLK
A
P2 OR BRN
P1 OR PUR
MAIN
START
5
1
GE/RBC BEATER MOTOR WIRING
CCWLE-RED OR T8 INTERNAL ON #5,BLACK OR T5 INTERNAL ON #A}
1
2
3
TORQUE CONTROL JUMPER FUNCTION
JUMPER FACTORY
INSTALLED
J1 PINS 1&2
45° LOCKOUT-INSTALL JUMPER TO ENABLE
(REQUIRES OPTIONAL DOOR SWITCH)
NO
J2 PINS 1&2
REFRIGERATION INTERVAL. NO JUMPER = 7
MINUTES, JUMPER INSTALLED = 12 MINUTES.
NO
J2 PINS 3&4
1-DAY LOCKOUT. INSTALL JUMPER TO ENABLE.
(REQUIRES OPTIONAL DOOR SWITCH)
NO
J2 PINS 5&6
4-DAY LOCKOUT. INSTALL JUMPER TO ENABLE.
(REQUIRES OPTIONAL DOOR SWITCH)
CUSTOMER
SPECIFIC
TORQUE CONTROL
IF 4 DAY LOCKOUT
IS REQUIRED, MOVE
JUMPER ONTO PINS
5&6
LINE
LOAD
BLK
WHT
GRN/YEL
F1
W2
W1
FUSE