Taylor model 430 torque shake/slush freezer Refrigerator User Manual


 
20
Troubleshooting Guide Model 430 Torque
Section 8 Troubleshooting Guide
PROBLEM PROBABLE CAUSE REMEDY PAGE
REF.
1. No product being
dispensed.
a. Power switch is in the “OFF”
position.
a. Place power switch in the
“AUTO” position.
15
b. Improper mixing of product. b. Carefully follow directions
for mixing product.
---
c. Inadequate mix in hopper. c. Fill hopper with mix. 16
d. Product frozen- up in freezing
cylinder.
d. Adjust viscosity adjustment
accordingly.
10
e. Unit out on reset. e. Place power switch in the
“OFF” position. Press the
reset button. Return
control switch to “AUTO”.
10
f. Beater assembly is not
rotating at all or
counterclockwise. Control
switch is not in “AUTO”.
f. The power switch must be
in “AUTO”. If beater is
rotating counterclockwise,
call service technician to
correct rotation.
1
g. Unit is unplugged. g. Plug in power cord. ---
h. Tripped circuit breaker or
blown fuse.
h. Reset circuit breaker or
replace fuse.
---
2. Unit will not operate in the
“AUTO” or “WASH” mode.
a. Unit unplugged at wall
receptacle.
a. Plug in power cord. ---
b. Tripped circuit breaker or
blown fuse.
b. Reset circuit breaker or
replace fuse.
---
c. Unit out on reset. c. Place the power switch in
the “OFF” position. Press
the reset button. Return
control switch to “AUTO”.
10
3. No compressor operation
in the “AUTO” mode.
a. Beater motor is out on
overload.
a. Place control switch in
“OFF” position. Press the
reset button. Return
control switch to “AUTO”.
10
b. Condenser dirty A/C. b. Clean condenser monthly. 18
4. Product too thick. a. Inadequate mix in hopper. a. Fill hopper with mix. 16
b. Improper mixing of product. b. Carefully follow directions
for mixing product.
---
c. The viscosity adjustment is
set incorrectly.
c. Adjust the viscosity control. 10
d. The torque arm is not
installed.
d. Install the torque arm. 13