SERVICE AND REPLACEMENT GUIDE
Your TOASTMASTER
®
XO–1N has been designed to be serviced quickly and easily. In fact, any individual with
average mechanical ability can do the work. Call TOASTMASTER
®
at (906) 863-4401 and ask for our Service
Department to order replacement parts, ask questions, or offer comments.
Our Service Department is available to you Monday through Friday from 8:00 a.m. to 4:30 p.m. (CST) should you nd
yourself with a situation or problem other than we have outlined. Our technicians are also available via pager from
7:00 a.m. to 10:00 p.m. during week-ends and holidays.
This SERVICE AND REPLACEMENT GUIDE has been prepared to cover most normal service problems. If this
“trouble–shooting” information does not provide a solution for your particular problem we ask that you call us for direct
assistance. Calling our Service Department before calling in a repair technician can usually save you both time and
unnecessary expense. We want to do everything we can to minimize your “down-time”.
You may need to remove an access panel for servicing. DO NOT allow any access panels to drop. When work on the
component is nished replace the panel with care, making sure that all wires are properly placed and not pulled or
pinched. If more than one component is being worked on try to remove only one component at a time.
TEMPERATURE CONTROL, How to Adjust:
A. Place a reliable thermometer (or the thermocouple of a test instrument) on a pan in the center of the Oven. Turn
the unit ON and set the Temperature Control [14] to its normal setting. Allow the equipment to reach a stable
operating temperature.
B. Compare the Temperature Control setting to the reading on the test instrument when the Temperature Control
Indicator Light [16] goes out. If there is a difference of more than 25° you may need to recalibrate the Temperature
Control. Please call the NU-VU
®
Service Department at (906) 863-4401 for the proper calibration procedures before
attempting to re-calibrate the Oven!!!
C. If the difference is less than 25° a simple dial adjustment may solve the problem:
1. Loosen the Knob of the Temperature Control by loosening the two set screws on the sides of the knob.
2. With the screws loosened, turn the knob so the white mark is aligned with the temperature reading from the
test instrument.
3. Tighten the set screw on the sides of the knob.
4. Check the control setting against the test instrument and repeat this procedure if necessary.
D. If this procedure fails to bring the temperature reading within the desired specs, please call the TOASTMASTER
®
Service Department for advanced instructions on calibrating the thermostat itself.