Unified Brands HY-6G(CE) Electric Steamer User Manual


 
14 OM/SM-HY-6G(CE)
OM/SM-HY-6G(CE)
14
7.0 - Maintenance
The HY-6G(CE) Steamer is designed for minimum
maintenance, and no user adjustments should be
necessary. Certain parts may need replacement after
prolonged use. If there is a need for service, only
Groen personnel or authorized Groen representatives
should perform the work.
Always supply water with a low mineral count that
meets the standards outlined in the Water
Conditioning section of this manual.
The unit does not contain fuses that could be
replaced by the operator.
If steam or condensate is seen leaking from around
the door, take the following steps:
1. Check the door gasket. Replace if it is cracked or
split.
2. Inspect the cooking chamber drain to be sure
it is not blocked.
3. Adjust the latch pin to allow for changes that
might occur as the gasket ages:
a. Loosen the lock nut at the base of the
latch pin. Turn the latch pin ¼ turn
clockwise, and re-tighten the lock nut.
b. After adjustment, run the unit to test for
further steam leakage
c. If there is still leakage, repeat the
adjustment.
d. Continue adjusting the pin clockwise until
the door fits tightly enough to prevent
leakage.
8.0 - Troubleshooting
This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is
a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an item
on the check list is marked with (X), it means that the work should be done by a factory-authorized service
representative.
SYMPTOM WHO WHAT TO CHECK
Pilot will not light User a. Are electrical connections made with a ground?
b. Is gas supply connection made?
c. Is pilot ignition switch on?
d. Is gas valve turned on?
e. Are building fuses or circuit breakers all right?
f. Are there drafts which could blow out the pilot?
Auth Service
Rep Only
g. Is spark ignition cable connected to module? (X)
Steam generator does not fill with
water.
User a. Is the ON/OFF touch pad depressed?
b. Is the water supply connected?
c. Is the water turned on?
d. Check for low water pressure (less than 210 kPa or
30 PSI).
e. Is the screen at the water connection clogged?
f. Has the steam generator been delimed?
No steam. User a. Is the ON/OFF touch pad depressed?
b. Is the water supply connected?
c. Is the water turned on?
d. Are steamer doors open?
e. Is the steam generator limed up?
Red light comes on after four
minutes.
User a. Is the water supply connected?
b. Is the water turned on?
c. Has the unit been delimed? (Refer to Cleaning
Section)
Excessive steam escaping from rear
of unit
User a. Is the water spray hose kinked or obstructed?
Auth Service
Rep Only
b. Is the water spray solenoid connected?(X)
c. Is the drain properly vented? (X)