To Align:
5. Place a piece of masking tape over the door pin
(bullet) hole in the door.
6. Close the door until the door pin just penetrates the
masking tape. Make sure the door pin contacts only
the door latch spring.
7. If door pin does not strike the center of the spring
hole in the U-channel, loosen the hinge-to-oven bolts
and align the door to the door pin. Tighten hinge-to-
oven mounting bolts.
8. You should be able to pull a dollar bill or comparable
piece of paper smoothly between the gasket and
oven cavity with the door closed. To adjust the hinge
side, loosen the door-to-hinge bolts and align the
door gasket with the oven cavity. Tighten the door-
to-hinge mounting bolts. To adjust the bullet side
refer to 10.30.
9. Operate the steamer and check for leaks.
10.25 Door Switch
P/N 096857
1. From the right side of the steamer with panel
removed, unplug the door switch from the cable
harness.
2. The switch (for normal door opening) is held in place
with two small screws. With a flat blade screwdriver,
remove these screws and the switch may be
removed.
3. To install screws for the door switch reverse the
above procedure.
4. If the door has been reversed and the switch must
be removed and replaced, refer to the top and left
side panel removal in Section 10.3 and then remove
the switch as above.
10.26 Door Reversing Procedures
1. Turn off steamer power and allow steamer to cool.
2. To remove door, support door while removing hinge-
to-steamer bolts.
3. Place door with hinge on a flat, clean table (or similar
support), with the gasket facing up. Be careful not to
scratch door surface.
4. Note and record distance between lock nut and end
of door locking pin (bullet). This information will be
needed during bullet installation described in Step 6.
5. Loosen lock nut with a wrench. Remove door locking
pin and lock nut.
6. Coat bullet threads with NEVER-SEEZ high
temperature compound. Install door locking pin and
lock nut directly across steamer cavity from old door
locking pin location. Install these items so that lock
nut-to-end of bullet distance is approximately the
same as measured in Step 4.
7. Remove the two truss head screws from above and
below the old bullet location and install them above
and below the new bullet location.
8. Remove screws and U-channel from the door. Take
the magnet and block assembly from present
location and place it at the opposite end of the door
channel, with the magnet facing outward from the
door.
9. Remove screws which secure the handle. Remove
door handle from cam.
10. Apply NEVER-SEEZ high temperature (rated for
250ºC) anti-seize and lubricating compound to the
cam and Locktite 242 to screw threads.
11. Turn handle and cam 180-degrees from their original
positions and install them on the door with screws.
Be sure handle and cam move smoothly.
12. Be sure door handle is in the DOWN position. Turn
U-channel 180-degrees from its original position,
hold door spring in U-channel open with a
screwdriver or similar tool, and install U-channel.
Don not install the screw at this time.
13. Check operation of the cam. Push up on the door
handle and check if the spring opens. If the spring
does not open, cam and spring are NOT correctly
aligned and problem must be corrected.
14. Apply a light amount of Locktite 242 to screws, then
install screws securing U-channel.
15. Apply Locktite 242 to the hinge-to-steamer bolts,
then install door and hinge mounting bolts. Do NOT
tighten mounting bolts at this time.
16. Align door to steamer. Refer to 10.24, Alignment
procedure.
IMPORTANT. When the door is reversed, the alternate
door switch (installed at time of manufacture) must be
connected to the circuit.
17. From the right side access to the upper portion of the
steamer, disconnect the two leads of the door
switch.