a. Set the timer to the desired time for timed
steaming.
b. Turn the timer knob to the manual ON
position for continuous steam.
c. Let the unit stay at standby temperature.
WARNING
WHEN YOU OPEN THE DOOR, STAY AWAY FROM
STEAM COMING OUT OF THE UNIT. THE STEAM
CAN CAUSE BURNS.
4.6.9 To shut down the unit, press the ON/OFF touch
pad into the off position. The steam generator
will then drain. You may also switch off the pilot
switch to conserve energy.
4.6.10 If the HY-6G(CE) Steamer behaves as
described, the unit is functioning correctly and
ready for use.
4.6.11 Automatic Operation of Pilot
Once the pilot burner is lit, it essentially functions as a
standing pilot. In this state, if the pilot is accidentally
extinguished (by a very strong gust of wind for example),
it will re-ignite automatically. The unit will completely shut
down for a few seconds while the pilot is re-ignited.
Then the unit will come back on and resume
operation in the mode and with the (running) timer
value existing just prior to shutdown. The pilot
switch may be turned off during “off hours” to
conserve energy.
After the unit has been running, if the pilot burner
ever fails to re-ignite automatically within 90
seconds, wait 5 minutes before you attempt to
reactivate it. In the unlikely event that ignition
problems persist, contact your authorized Groen
Service Agency.
NOTE: For operation at high altitudes (2000 feet and
above) please consult the Groen Food Service
Engineering Department.
4.7 Gas Type Conversion (See Paragraph 4.3.1 for
important information for gas conversion. Verify
the type of gas to be used).
To change the type of gas used (e.g. G20 to/from
G31) change the following:
Burner injector
Pressure setting on Main Gas Valve
Data plate
Gas pressure Regulator Springs
The governor spring does not need to be changed;
only the pressure setting. ALL CONVERSIONS
MUST BE FOR APPROVED GAS IN THE
COUNTRIES LISTED IN PARAGRAPH 4.3.1