D. VM-2SL Sliding Glass Door Shim Insertion Instructions
If VM-2SL cabinet has gap(s) between the sliding glass door and frame, contact factory and
request door roller assembly shim(s) under part number 05314501. Following are step by step
guidelines that will assist in closing any gap(s).
*Note: Pay close attention to roller assembly location and numbered arrows!
Instructions
:
20
If "Gap" is around
this area (arrow 2),
place shim(s) under
roller assembly at
the same location.
If "Gap" is around
this area (arrow 4),
place shim(s) under
roller assembly at
the same location.
If "Gap" is around
this area (arrow 3),
place shim(s) under
roller assembly
where the opposite
arrow with "3" is
located (diagonally
across).
Figure 1
Section 5 - Service
Section 5 - Service
If "Gap" is around
this area (arrow 1),
place shim(s) under
roller assembly
where the opposite
arrow with "1" is
located (diagonally
across).