Vulcan-Hart F-37418 Range User Manual


 
Page 12 of 36
8. Test the oven to verify proper operation.
Figure 9: S Model Pilot Safety Valve Removal
Temperature Control (S Model)
WARNING: Always perform the Electrical Lockout/Tagout procedure before removing
any sheet metal panels or attempting to service this equipment. Failure to comply with
this procedure can cause property damage, injury or death.
WARNING: Perform the GAS LOCKOUT/TAGOUT procedure before servicing the unit.
1. Perform the PILOT SAFETY VALVE AND TEMPERATURE CONTROL
ASSEMBLY removal procedure.
2. Remove the fitting from the top of the temperature control.
3. Remove the screw securing the temperature control to the gas mount bracket.
4. Remove the temperature control from the pipe nipple.
5. Remove any residual tape from the fitting and the pipe nipple and install with new gas-
rated (Yellow) Teflon tape.
WARNING: All gas joints disturbed during servicing must be checked for leaks.
Do not use an open flame. Use a hazardous gas tester or a soap and water
solution (Bubbles indicate a gas leak). Failure to comply can cause property
damage, injury or death.
6. Reverse the procedure to install the temperature control.
7. Test the oven to verify proper operation.
Figure 10: S Model Temperature Control Removal
Temperature Control (C Model)
WARNING: Always perform the Electrical Lockout/Tagout procedure before removing
any sheet metal panels or attempting to service this equipment. Failure to comply with
this procedure can cause property damage, injury or death.
WARNING: Perform the GAS LOCKOUT/TAGOUT procedure before servicing the unit.