Figure 15: C Model Shut-Off Valve Removal
Oven Pilot Assembly
WARNING: Always perform the Electrical Lockout/Tagout procedure before removing
any sheet metal panels or attempting to service this equipment. Failure to comply with
this procedure can cause property damage, injury or death.
WARNING: Perform the GAS LOCKOUT/TAGOUT procedure before servicing the unit.
NOTE: The oven pilot assembly is attached to the burner assembly and is located behind the
kick panel.
1. Perform the ELECTRICAL LOCKOUT/TAGOUT procedure.
2. Perform the GAS LOCKOUT/TAGOUT procedure.
3. Perform the KICK PANEL removal procedure.
4. Remove the food deflector panel.
5. Remove the gas flex line to the burner nozzle.
6. Remove the two (2) bolts securing the burner drawer box to the oven.
7. Pull the burner drawer box out from the oven.
Figure 16: Burner Drawer Removal
8. Remove the two (2) screws securing the oven pilot assembly to the oven burner
deflector and remove the pilot assembly.
WARNING: All gas joints disturbed during servicing must be checked for leaks.
Do not use an open flame. Use a hazardous gas tester or a soap and water
solution (Bubbles indicate a gas leak). Failure to comply can cause property
damage, injury or death.
9. Reverse the procedure to install the oven pilot assembly.
10. Test the oven to verify proper operation.
Figure 17: Oven Pilot Assembly Removal