Vulcan-Hart k20GLT Hot Beverage Maker User Manual


 
GAS SUPPLY PRESSURES
GAS TYPE Manifold (in W.C.) NOMINAL (in W.C.) MIN (in W.C.) MAX (in W.C.)
Natural
Low Speed * - 0.27 to 0.30
High Speed - 1.91 to 1.98
7 5 14
Propane
Low Speed * - 0.27 to 0.30
High Speed - 1.91 to 1.98
11 11 13
* Low Speed – Blower operates at low speed during trial for ignition (approximately 7 seconds). Ignition
is successful and burner lights. Blower switches to high speed for normal operation approximately 8
seconds later (total time delay of 15 sec. to high speed) and runs until set point temperature is satisfied.
Cycle repeats upon call for heat.
Kettle Rating
All models listed on front cover have an input BTU rating of 100,000 BTU/HR.
OPERATION, CLEANING AND MAINTAINENCE
Refer to F35461 Installation & Operation Manual for specific instructions. The manual includes:
A page from the Stainless Steel Care and Cleaning Guide for proper care and cleaning of stainless steel.
Draw-Off Valve and Plug Valve dissassembly & cleaning instructions.
K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - GENERAL
F45461 Rev. A (0713) Page 6 of 44