5. Remove the top section burner valve knobs.
6. Remove screws holding the control panel in place.
7. Disconnect the thermostat burner tubing (Fig. 31).
8. Remove top burners, if required, to access the thermostat (Fig. 32).
STANDARD OVEN & GRIDDLE
THERMOSTAT REPLACEMENT (Cont.)
Fig. 31
Fig. 32
Fig. 30
4. From inside the oven, straighten the capillary lead. From the opening in the oven top section, pull the capillary out
of the oven cavity (Fig. 30).