Vulcan-Hart ML-52947 Range User Manual


 
9
SERVICING SIMPLE CHECKS AND ADJUSTMENTS (Cont.)
3. Pilot Flame Height
TOOLS REQUIRED: Standard flat blade screwdriver.
Top Burners: To adjust pilot flame height of the unit top burners, locate the pilot adjustment screws found on the front
manifold pipe. It is not necessary to remove the manifold cover, as adjustment access holes have been provided in the
panel. With screwdriver, turn the adjustment screw of the pilot valve experiencing the pilot flame height problems
(Fig. 3). Rotate the screw clockwise to decrease and counterclockwise to increase the flame height.
Fig. 3
Oven: On rare occasions, the standard or convection oven pilot may need adjustment. To do this:
1. Remove the pilot adjustment cap (Fig. 4)
Fig. 4
OUT
IN
R
O
B
E
R
T
S
H
A
W
C
R
A
Y
S
O
N
PL-50117
Oven Pilot
Control Button
Pilot Adjusting Cap