Vulcan-Hart ML-52947 Range User Manual


 
42
CONVECTION OVEN MOTOR AND DOOR SWITCH CHECK,
REPLACEMENT (Cont.)
Fig. 52
4. Remove wire connectors while observing their locations for reference when reassembling new switch.
5. Install new switch by reversing Steps 1 through 5.
CONVECTION OVEN MOTOR REPLACEMENT (90 Series Only)
TOOLS REQUIRED:
7
/16" socket,
5
/16" socket, socket driver,
5
/16" open end wrench, and standard blade screwdriver.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO
INDICATE YOU ARE WORKING ON THE CIRCUIT.
1. Disconnect main gas and electrical supplies.
2. Open oven cavity door and allow unit to cool.
3. Remove all oven racks.
4. Remove (2) #10 sheet metal screws securing snorkel tube to oven cavity (Fig. 53).
3. Disengage (2) screws and (2) nuts from micro switch housing to access switch (Fig. 52).