Vulcan-Hart RRE24D Cooktop User Manual


 
-
4 -
Close Backwall, Rigid Conduit Electrical Connections
1. Lift the front of the griddle top only as far as necessary to gain access to the terminal box on the
body’s inside rear.
2. Prop the griddle top up securely to prevent it from failing.
Do not lift the griddle top too high, as thermostat and unit terminals may be damaged
beyond repair.
3. Remove the fastener near the bottom of the terminal box and slide the enclosure up to expose
knockouts.
4. Connect griddle’s line leads to the supply wires as shown in the applicable wiring diagram. Do
not disturb the griddle wiring.
5. Slide enclosure down and secure with fastener.
6. Lower the griddle top, making sure that it is securely in place.
Since the griddle is not fused, you must connect it to a fused circuit equipped with a
suitable disconnecting means as required by local authorities.
*NOTE: Two separate conduit connections must be made: each connection carries one-half of the
r
ated load.
**NOTE: Two separate conduit connections must be made: one connection carries 16.2 KW, the other
connection carries 10.8 KW.
STANDARDVOLTAGES208VOLTSOR240VOLTS50/60Hz.SINGLEORTHREEPHASE
480VOLTS50/60Hz.THREEPHASEONLY
 TOTAL TOTAL
3PHASE
LOADING NOMINALAMPSPERLINEWIRECONN.*
MODEL CONN. KW KWPERPHASE 3PHASE 1PHASE
NO. KW PER PERCONN.* 208VOLT 240VOLT 480VOLT 208 240
  CONN XY YZ XZ X Y Z X Y Z X Y Z VOLTVOLT
RRE24D 10.8 10.8 5.4 0.0 5.4 45.026.026.0 39.022.5 22.519.5 11.3 11.3 51.9 45.0
RRE36D 16.2 16.2 5.4 5.4 5.4 45.045.045.0 39.039.0 39.019.5 19.5 19.5 77.9 67.5
RRE48D 21.6 21.6 10.8 5.4 5.4 68.768.745.2 59.559.5 39.029.8 29.8 19.5103.9 90.0
RRE60D** 27.0 16.2 5.4 5.4 5.4 45.045.045.0 39.039.0 39.019.5 19.5 19.5 77.9 67.5
  10.8 5.4 0.0 5.4 45.0 26.0 26.039.0 22.522.5 19.511.3 11.3 51.9 45.0
RRE72D* 32.4 16.2 5.4 5.4 5.4 45.045.045.0 39.039.0 39.019.5 19.5 19.5 77.9 67.5
  16.2 5.4 5.4 5.4 45.0 45.0 45.039.0 39.039.0 19.519.5 19.5 77.9 67.5