Vulcan-Hart VP18 ML-138089 Food Saver User Manual


 
V SERIES HOLDING, TRANSPORT & PROOFING CABINET F-41190 (09-10)
11
TROUBLESHOOTING
SYMPTOMS
POSSIBLE CAUSES
REMEDY
Cabinet not operating
Cabinet not connected to
power source.
Connect cabinet to power source.
No power.
Check circuit breaker
Check GFCI
GFCI or Ground Fault
Circuit Indicator tripped
Moisture problem.
Dry moisture problem.
Shorted element
Contact Authorized Service
Provider.
Pinched/damaged wire.
Contact Authorized Service
Provider.
Damaged power cord.
Contact Authorized Service
Provider.
Cabinet is connected to
power source, switch is
ON, circuit breaker is ON,
but cabinet is not heating.
Defective: element,
thermometer, thermostat,
etc.
Contact Authorized Service
Provider.
Proof/Hold Indicator Light
not lit.
Light faulty
Contact Authorized Service
Provider.
Cabinet does not heat
properly
Door not shut properly or
needs adjustment
Check door seal and Contact
Authorized Service Provider.
Defective: element,
thermometer, thermostat,
thermostat requires
adjustment
Contact Authorized Service
Provider.
Fan not operating
ON/OFF switch not ON
Turn ON/OFF switch ON
Defective fan.
Contact Authorized Service
Provider.
Excessive Humidity
Too much water in Water
Pan
Adjust Water
Drain hole clogged for Drip
Pan underneath Cabinet
Clean drainage hole and check Drip
Pan
SERVICE & PARTS INFORMATION
To obtain Service and Parts information concerning this model, contact Vulcan-Hart
Service Department at the address listed on the front cover of this manual, or refer to
our website: www.vulcanhart.com for a complete listing of Authorized Service and Parts
depots.
Customer Service 1-800-814-2028
Technical Service 1-800-814-2028
Service Parts 1-800-814-2028
When calling for service, have the model number and serial number available.