Temperature Data from Testing
Temperature \ Test (time)
First (after 5 mins)
Second (after 8 hrs)
Third (after 24 hours)
Inlet Air
Outlet Air
Evaporator
(Front) Side
Differential
(Inlet – Outlet = _; ideally 10°F-15°F)
Inlet Air (ideally <90°F)
Outlet Air (ideally <120°F)
Condenser (Back)
Side
Differential
(Inlet – Outlet = _; ideally around 30°F)
-26-
Temperature Testing Locations
Inlet Air – Evaporator (Front) Side
Outlet Air – Evaporator (Front) Side*
Inlet Air – Condenser (Back) Side•
Outlet Air – Condenser (Back) side*
*When measuring outlet air temperature on both sides of the unit (from the
circular fans), hold the thermostat at the outer edges of one of the circular fans.
Third Temperature Test:
10. After the unit has run for 24hours, perform the third and last temperature test.
11. Record information and calculate temperature differential in table below.