Yeoman YM-E9001FLA Cooktop User Manual


 
7
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATIONS
SITE REQUIREMENTS
ALL INGLENOOK FIREPLACE OPENINGS:
For all models the dimensions required for an inglenook
installation can be calculated by adding 225mm (9") to
the height of the appliance and 150mm (6") to each side.
An additional 50mm (2") must be added to the depth to
provide adequate space behind the appliance.
These instructions cover the following models:
Exmoor - Small YM-E9001FLA
Dartmoor - Single Door YM-E5201FLA
- Double Door YM-E5202FLA
EXMOOR DIMENSIONS
1
Low canopy 671mm
Flat top 526mm
Low canopy 477mm
Flat top 438mm
Canopy 309mm
Flat top 285mm
303mm
10mm
451mm
300mm
DARTMOOR DIMENSIONS
2
Flat top 667mm
Flat top 347mm
351mm
34mm
651mm
360mm
Flat top 576mm
These appliances have 3 modes of operation:
Flame effect only - with brightness and flame colour
adjustment
Flame effect + 1kW heating
Flame effect + 2kW heating
A 230v 13amp 50Hz supply is required
Maximum power consumption is 2064 watts
THIS APPLIANCE MUST BE EARTHED
A 1.8 metre lead with plug containing a 13 amp fuse is
supplied. Only use a 13 amp fuse with this appliance.
Remote control handset battery (CR2032)