CONNECTION TO SYSTEMS WITH JUPITER−CONTROLLED ROUTER ONLY
SlimLine UMDs are connected to the Jupiter CM 4000 through a SlimLine Controller, which has RJ45 ports for Cat 5 Ethernet
cable connection to 16 UMDs. Power is provided to the UMDs through the Cat 5 cables. See Figure 2−96.
Figure 2−96. SlimLine UMD
Status Display installation.
Up to 16 UMDs per SlimLine controller
MPK bus
Serial data cable (see page 2−63)
Serial
Port
CM 4000 System Controller
Sync ref. See
pg. 2−64
Cat 5 cable
(see Note 2 on page 2−82)
SlimLine UMD Controller
MPK bus loop to additional SlimLine Controllers
AC
power
LAN
Software Configuration
Under monitor status displays must be identified as MPK devices. See page 5−116.
If SlimLine UMD tally light operation is needed, additional configuration will be required:
For the Jupiter Standard Tally application, there must be an MPK table entry for an “MI 3040/T” whether it is
physically present or not (see page 5−117). Entries to the Tally Relay and Tally Dependency tables will also be
needed (see pages 5−152 and 5−158).