Sense Data Values
137ESL E-Series Tape Library User’s Guide
583 E0EXTENSION INVALID START CONDITION
Extension hardware condition is unknown. Issue a Rezero Unit
command.
583 F0EXTENSION INVALID COMMAND
Extension hardware was commanded to a position out of the systems
mechanical limits.
4 84 See
Table 23
VERTICAL HARDWARE FAILURE
Vertical hardware internal failure. Call Technical Support.
584 E0VERTICAL INVALID START CONDITION
Vertical hardware condition is unknown. Issue a Rezero Unit
command.
584 F0VERTICAL INVALID COMMAND
Vertical hardware commanded to position out of system mechanical
limits. Issue a Rezero Unit command. If the problem persists, calibrate
the library.
4 85 See
Table 23
HORIZONTAL HARDWARE FAILURE
Horizontal hardware failure. Call Technical Support.
585 E0HORIZONTAL INVALID START CONDITION
Horizontal hardware condition is unknown. Issue a Rezero Unit
command.
585 F0HORIZONTAL INVALID COMMAND
Horizontal hardware commanded to position out of system
mechanical limits. Issue a Rezero Unit command. If the problem
persists, calibrate the library.
4 87 See
Table 23
DEPTH HARDWARE FAILURE
Depth hardware failure. Call Technical Support.
587 E0DEPTH INVALID START CONDITION
Depth hardware condition is unknown. Issue a Rezero Unit
command.
Table 22: Sense data values (Hexadecimal) (Continued)
Sense
Key
ASC ASCQ Message Name/Description