A SERVICE OF

logo

Sense Data Values
138 ESL E-Series Tape Library User’s Guide
587 F0DEPTH INVALID COMMAND
Depth hardware commanded to position out of system mechanical
limits. Issue a Rezero Unit command. If the problem persists, calibrate
the library.
48800WARNING SAFE TEMPERATURE EXCEEDED
This is only a warning that the temperature in the library exceeds the
normal operational temperature (96.8
o
F).
48801MAXIMUM TEMPERATURE EXCEEDED
The robot in the cabinet that has overheated turns off and remains off
until the temperature returns to an acceptable level (59-90
o
F).
48900-FFVISION HARDWARE FAILURE
Vision internal failure. Call Technical Support.
58A 02UNCALIBRATED POSITION
System requires calibration.
68A 02CALIBRATION FAILURE
Check slots, cartridges, all internal elements.
4 8B See
Table 23
CLM HARDWARE FAILURE
CLM failure. Call Technical Support.
58B E0CLM INVALID START CONDITION
CLM hardware condition is unknown. Issue a Rezero Unit command.
58B F0CLM INVALID COMMAND
CLM hardware commanded to position out of system mechanical
limits. Issue a Rezero Unit command. If the problem persists, calibrate
the library.
B8BC0TRANSPORT FULL
The CLM contains a cartridge. Issue a command to retrieve the
cartridge from the CLM and place it in either a bin or a tape drive.
Table 22: Sense data values (Hexadecimal) (Continued)
Sense
Key
ASC ASCQ Message Name/Description