40 Xanbus Automatic Generator Start (AGS) Owner’s Guide
Configuration of the Xanbus AGS
The Configuration Menu
The Configuration Menu is where specific start-stop parameters are set.
This menu contains the following settings:
• "QT En"
• "QT Begin"
• "QT End"
• "Gen Type"
• "Cfg Trigger"
• "Cfg Gen"
• "Restore Defaults"
QT En
Full name Quiet Time Enable
Purpose "QT En" enables or disables the Quiet Time functionality of the
AGS. Quiet time refers to a period of time when the generator should not
run.
Dependencies "QT En" requires the AGS to be in Automatic mode.
Setting "QT En" to [Enable] requires that parameters be set for the "QT
Begin" and "QT End".
When to use Set "QT En" to [Enabled] when there is a period of time
when it is not desired for the generator to run. The AGS will ignore all
automatic start triggers during the time set in "QT Begin" and "QT
Begin".
When there are no preferences or restrictions for when the generator should
run, set "QT En" to [Disabled]. When [Disabled] is selected, the AGS will
ignore the times set for "QT Begin" and "QT End".
Considerations Quiet Time prevents the automatic starting of the
generator regardless of battery condition.
Value Description
Enabled/Disabled Enables or disables the Quiet Time functionality.