975-0082-01-01 65
Operation of the Xanbus AGS
Starting and Stopping the Generator
Use the AGS to start or stop the generator manually using the Xanbus
System Control Panel (SCP) or automatically in response to an electrical
system condition.
To set the AGS to start and stop the generator automatically:
1. On the AGS menu, highlight GenMode and press Enter.
2. Use the arrow button to select [Automatic].
3. Press Enter.
To start the generator manually:
1. On the AGS menu, highlight GenMode and press Enter.
2. Use the arrow button to select [ManualOn].
3. Press Enter.
To stop the generator manually:
1. On the AGS menu, highlight GenMode and press Enter.
2. Use the arrow button to select [ManualOff].
3. Press Enter.
IMPORTANT:
To avoid AGS faults, try not to combine automatic and
external manual starts and stops.
When the generator has been started automatically, allow it to stop
automatically unless a situation occurs that requires the generator to be
stopped urgently.
Likewise, if the generator has been started manually, ensure that it is
stopped manually. Only the "Max Run Time" setting can automatically
stop the generator after it has been started manually.
Figure 34
Starting and Stopping the Generator
XAGS 00: Setup
Mode
Clear Faults Warnings
View Device Info
[Operating]
GenMode [ManualOff]
System Status
BatLev
Load
AC1 1150W 3202V
E--F
1235W
Battery 20.4A 53.9V
Menu
Select Device
FSW3012
EMS
System Settings
XAGS