A SERVICE OF

logo

66 Xanbus Automatic Generator Start (AGS) Owner’s Guide
Operation of the Xanbus AGS
Using Quiet Time
Use the Quiet Time feature to ensure that the AGS will not start the
generator during the night or during times that conflict with local noise
restrictions.
Using Quiet Time involves three steps.
1. "QT En" must be set to [Enabled]. The default setting is [Enabled].
2. "QT Begin" must have an appropriate time set for Quiet Time to start
on schedule. The default setting for "QT Begin" is [9:00 PM] or 21:00
if using a 24-hour clock.
3. "QT End" must have an appropriate time set for Quiet Time to stop on
schedule. The default setting for "QT End" is [8:00 AM] or 8:00 on
the 24-hour clock.
For more information about Quiet Time settings, see “QT En” on page 40,
“QT Begin” on page 41, and “QT End” on page 42.
To enable Quiet Time:
1. On the Auto Gen Start menu, use the arrow buttons to highlight "QT
En".
2. Press Enter.
3. Use the arrow buttons to select [Enabled].
4. Press Enter.
To set the beginning of Quiet Time:
1. On the Auto Gen Start menu, use the arrow buttons to highlight "QT
Begin", then press Enter.
2. Use the arrow buttons to select the hour, then press Enter.
3. Use the arrow buttons to select the minutes, then press Enter.
If the 24-hour clock is being used, go to step 5.
4. Use the arrow buttons to select AM or PM, then press Enter.
5. Press Exit twice to return to the System Home screen.
To set the end of Quiet Time:
1. On the Auto Gen Start menu, use the arrow buttons to highlight "QT
End", then press Enter.
2. Use the arrow buttons to select the hour, then press Enter.
3. Use the arrow buttons to select the minute, then press Enter.
If the 24-hour clock is being used, go to step 5.
4. Use the arrow buttons to select AM or PM, then press Enter.
5. Press Exit twice to return to the System screen.
Figure 35
Using the Quiet Time Feature
System Status
BatLev
Load
AC1 1150W 3202V
E--F
1235W
Battery 20.4A 53.9V
Menu
Select Device
FSW3012
EMS
System Settings
XAGS
XAGS 00: Setup
Clear Faults Warnings
View Device Info
Advanced Settings
GenMode [ManualOff]
XAGS 00: Adv
QT End
Gen Type
[Enabled]
QT En
QT Begin [10:00AM]
[7:00AM]
[2]
F
SW System Home
S
creen
Select Device Menu AGS Menu Set Quiet Time settings