3M 200a Food Saver User Manual


 
12
Installation and Set-Up (Continued)
BOX SIZE CAPACITY OF CASE SEALER
At its factory setting, the case sealer handles
box sizes up to 620 mm [24.5 in] maximum
height. If larger capacity is needed, the machine
can be adjusted to accommodate boxes up to
725 mm [28.5 in] high. Refer to "Special Set-Up
Procedure  Box and Machine Bed Height
Range", page 24. Note  Adjusting machine
to accommodate 725 mm [28.5 in] high boxes
also increases minimum box size to 165 mm
[6.5 in].
ELECTRICAL CONNECTION AND CONTROLS
The electrical control box, located on the lower
right side of the machine frame, contains the
pre-set circuit breaker. The control box can be
located on the opposite side of the machine
frame if desired.
A standard three conductor power cord with plug
is provided at the back of the electrical control
box for 115 Volt, 60 Hz., 1.9 Amp electrical
service. The receptacle providing this service
shall be properly grounded. Before the power
cord is plugged into 115 Volt, 60 Hz outlet make
sure that all packaging materials and tools are
removed from the machine. Do not plug
electrical cord into outlet until ready to run
machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of AWG 16 [1.5 mm dia],
have a maximum length of 30.5 m [100 ft], and
must be properly grounded.
Note  Machines outside the U.S. may be
equipped with 220/240 Volt, 50 Hz systems or
other electrical requirements compatible with
local practice.
INITIAL START-UP OF CASE SEALER
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for tape
loading and start-up to be sure case sealer is
properly adjusted to run boxes
WARNING  To prevent shock and
fire hazard: Position extension cord
where it will be out of the way of foot or
vehicle traffic. Extension cord is only for
temporary use  do not use for a
permanent installation.