3M 200a Food Saver User Manual


 
20
Adjustments (Continued)
WARNING  Turn off electrical power supply and disconnect power cord from electrical supply
before beginning adjustments. If power cord is not disconnected, severe injury to personnel
could result.
Refer to Figure 5-2 and adjust belt tension as follows:
1. Remove and retain center plate and four screws.
2. Loosen, but do not remove, M10 lock nut with a 17 mm open end wrench.
3. Reset the tension on the drive belt as needed. Use M6 hex wrench and adjust the M8 socket head tension
screws in (clockwise) to increase tension or out (counterclockwise) to decrease tension. Tighten lock nut to
secure tension setting.
4. Replace center plate and secure with original screws.
Figure 5-2  Box Drive Belt Tension Adjustment (Machine Bed Infeed End)