32
Special Set-Up Procedure (continued)
Moving the outer columns to the upper set of
mounting holes increases the maximum box size
(height) handled by the case sealer from 620mm
[24-1/2 inches] to 725mm [28-1/2 inches]. Note –
this also increases the minimum box height from
120 mm [4-3/4 inches] to 210mm [8-1/4 inches].
13.11.4 Box Height Range
(Outer Column – Re-Positioning)
To Re-position the outer columns:
1. Remove special nut from the bottom of each
column lead screw - Figure 13-11A.
2. Remove plastic column cap from the top of each
outer column as shown in Figure 13-11B.
3. Crank upper assembly up, out of plastic nuts.
Lift upper assembly up and out of outer columns.
Be careful not to damage lead screws.
Figure 13-11C.
• To reduce the risk associated with
mechanical and electrical hazards:
− Turn electrical and air supply off and
disconnect before performing any
adjustments, maintenance, or servicing the
machine or taping heads
WARNING
•
To reduce the risk associated with
muscle strain:
− Use the appropriate rigging and
material handling equipment when lifting or
repositioning this equipment
− Use proper body mechanics when
removing or installing taping heads that are
moderately heavy or may be considered
awkward to lift
WARNING
13-MAINTENANCE AND REPAIRS (continued)
2011 September
800a3-NA