Alto-Shaam FryTech Series Fryer User Manual


 
Gas Fryer Operation & Care Manual • 20
O P E R A T I O N
FILTER CLEANING & MAINTENANCE
NOTE:
Make certain to use hand protection
when working with hot surfaces.
REUSABLE MESH FILTER OPTION:
Clean the reusable mesh filter (FI-27014) by spraying
thoroughly with hot water. DO NOT clean in the
dishwasher. DO NOT
use detergents to clean. Detergents
and detergent residues will significantly reduce the life of
oil and shortening products.
Make certain the filter is performing efficiently by
inspecting the filter each time it is cleaned. Examine for
cuts and holes. For the best results, replace the filter
whenever necessary.
Make certain the filter is securely fastened to the support
basket before returning the assembly to the trolley.
To discard deteriorated oil/shortening, the trolley can be
pulled from the fryer and can be rolled to a convenient
location for use with a pumping device.
ALWAYS MAKE CERTAIN THE TROLLEY IS
PROPERLY POSITIONED BENEATH THE FRYER
BEFORE OPERATION.
C A U T I O N
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN IN
OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
OIL FILTRATION INSTRUCTIONS (FOR UNITS WITH INSTALLED OPTION)
C A U T I O N
A WORN FILTER WILL AFFECT
PRODUCT FRYING RESULTS.
C A U T I O N
TO PREVENT FILTER DAMAGE, DO NOT USE SHARP
IMPLEMENTS TO REMOVE SCRAPS FROM THE FILTER.
W A R N I N G
TO AVOID PERSONAL INJURY, USE
CAUTION WHEN SURFACES BECOME
SLIPPERY DUE TO SPILLED OR
DRIPPING OIL.