Gas Fryer Operation & Care Manual • 21
O P E R A T I O N
CLEANING & MAINTENANCE
OIL DISCARD HOSE OPTION:
The oil discard hose option (HO-27686) is available
as an option to assist both the boil-out and
filtration operation.
With the discard hose attached to the nozzle
connection, place the Kettle/Nozzle selector
in the “NOZZLE ON” position.
The drain can be placed in the “OPEN” or
“CLOSED” position as required.
Disconnect hose following use and return the
selector to the “NOZZLE OFF” position.
Nozzle will contain a small amount of oil after use.
Dispose of properly.
OIL FILTRATION INSTRUCTIONS (FOR UNITS WITH INSTALLED OPTION)
D A N G E R
TO AVOID SERIOUS PERSONAL
INJURY DO NOT STAND ON THE
FRYER OR FRYER COVER. THE
FRYER COVER IS DESIGNED TO
HOLD A MAXIMUM OF 10-POUNDS
(4,5 KG) OF WEIGHT.
ASF-75G, 120V WITH FILTRATION
NOZZLE
KETTLE
SELECTOR
N
OZZLE
C
ONNECTION
NOZZLE
ON
NOZZLE
OFF