ELECTRICAL CONNECTION
INSTALLATION
DANGER
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
INTERNAL
GROUND STUD
CUSTOMER MUST SUPPLY CORD
INCOMING ELECTRICAL TERMINALS
APPLIES TO 208-240V & 380-415V UNITS
L1
L2
L3
N
Ground
EQUIPOTENTIAL
GROUND SCREW
380-415V ONLY
DANGER
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
Top/Back of unit
NOTE: Where local codes and CE regulatory
requirements apply, appliances must
be connected to an electrical circuit that
is protected by an external GFCI type 2
outlet.
When required, recommended ground
fault for Combitherm ovens is an
appropriately sized breaker with
built-in 30mA ground fault protection.