9
Converting Type 2 Pressure Regulator for Use with
LP/Propane
1. Remove pressure regulator cap with a
wrench.
2. Reverse pressure regulator cap.
• Cap must show “LP”.
3. Place pressure regulator cap on pressure regulator
and tighten.
Cap
LP
Type 2 Pressure Regulator
Converting Surface Burners for Use with LP\Propane
1. Remove 4 burner control knobs from range.
• Exposes 2 screws on burner control panel.
2. Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
• After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside. See
Pivot Point
in figure.
• Gas valve and orifice hood are visible after burner
control panel is removed.
A
B
C
D
A—Burner Control Knob
B—Pivot Point
C—Burner Control Panel
D—Screw
Burner Control Panel
4. While facing range front, turn orifice hoods
counterclockwise 1½ to 2 turns or until snug.
• Use ½ inch open end or 90° offset open end
wrench.
• Do not over tighten orifice hoods. If orifice hoods are
over tightened, gas supply can be cutoff or orifice
hoods can strip.
5. Open air shutter fully.
A
B
Open Fully
A—Orifice Hood
B—Air Shutter
Converting Surface Burners for Use with LP\Propane
6. Reassemble burner control panel after adjusting air
shutter.
• See
Adjusting Surface Burner Flame
section.