Broan 441 Ventilation Hood User Manual


 
19. REINSTALL FILTERS
1. Using a Phillips no. 2 screwdriver, assemble the knob to each filter.
NOTE: The screw MUST BE on filter tabs side. See illustration at right.
CAUTION
Remove protective plastic film covering filters before installing them.
HO0139
- 11 -
2. Rest rear filters edge on filter springs (B) in the power pack.
3. Using knob, tilt up the filters into position. Make sure filter tabs (C) are securely
engaged in power pack front edge after installation.
HD0373
B
C
20. LIGHT BULBS
This power pack requires shielded halogen lamps (120 V, 50 W max., MR16 or PAR16 with GU10 base), included.
1. Install the lamps by placing the bulb leads into their grooves in the socket.
2. Gently push upwards and turn clockwise until secure.
To remove lamps, gently push upwards and turn counterclockwise to disengage
bulb leads from their grooves.
NOTE: If need be, use a rubber dishwashing glove to add grip when removing the
bulb.
12
HO0090
WARNING
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of
personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroïc lamp, a
lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.
!
Connect cable using provided wire connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and GREEN
or BARE wire under ground screw (A). DO NOT FORGET TO CONNECT
THE GROUND.
HE0059
A