Bryant 3163 Refrigerator User Manual


 
YES
No Spark at Burner
Is 12 VDC at
input of 1
amp fuse?
NO
YES
Is 12 VDC
at output of
1 amp fuse?
NO
Replace 1 amp
fuse and start
refrigerator.
Correct DC
source to 1
amp fuse.
Is selector
switch set
to Gas?
NO
YES
Set selector
switch to Gas
and start
refrigerator.
Is 12 VDC at
input of 20
AMP fuse?
NO
YES
Correct DC
source to 20
amp fuse.
Is 12 VDC
present at
terminal block?
NO
YES
Correct DC
source and
start refrigerator.
Is circuit breaker
tripped or fuse
blown? (DC
to refrigerator)
YES
NO
Reset breaker
or replace fuse
and start
refrigerator.
Is thermostat
set to start?
NO
YES
Set thermostat
to start and
light refrigerator.
Is 12 VDC at
output of
selector switch?
NO
YES
Establish DC
supply to
relighter.
Replace
selector switch
and start
refrigerator.
Remove spark
electrode wire
from relighter.
YES
Is 12 VDC at
T1(+) & T3(-)
of relighter?
NO
YES
Check electrode
continuity -
must read
.
NO
Replace
electrode
assembly
Is relighter
sparking?
NO
YES
Is electrode
positioned 1/8"
max. above
burner?
NO
YES
Replace
relighter.
Adjust electrode
to 1/16" min. -
1/8" max.
above burner.
Specifications
Gas Pressure: 10.5" W.C. - 11" W.C. DC Volta
g
e: 10.5 - 15.4 VDC
Install short
jumper wire from
relighter to within
1/8" of ground
Note: If the negative DC supply connection is lost, the flame indicator light will remain on all the time, even without
the flame present.
Is 12 VDC
at input of
selector switch?
NO
Correct DC
to switch
and start
refrigerator.
14