Bryant 3163 Refrigerator User Manual


 
Rialta
1. Turn off the
g
as suppl
y
at the main tank.
2. Turn the refri
g
erator’s mode selector to "OFF".
3. Remove the refri
g
erator’s s
y
stem cover located
on the left front of the refri
g
erator b
y
removin
g
5
retainin
g
screws.
4. Remove 5 retainin
g
screws securin
g
the refri
g
-
erator to the enclosure.
5. Remove the drawer directl
y
above the refri
g
erator.
6. Turn the manual shut-off valve located on top of
the refri
g
erator to "OFF". See Fi
g
ure 12.
7. Disconnect the vehicle’s 12 volt DC suppl
y
wires
from the refri
g
erator’s terminal block.
8. Disconnect the LP
g
as suppl
y
line from the refri
g
-
erator’s manual shut-off valve. See Fi
g
ure 12.
CAUTION
:
To prevent gas leaks and damage to
the gas supply lines and fittings,
use two wrenches when connect-
ing or disconnecting gas fittings.
9. Disconnect the refri
g
erator’s AC power cord from
the wall receptacle.
10. Open the cabinet door to the left of the refri
g
era-
tor. Remove the access panel at the rear of the
cabinet. This will allow access to the refri
g
erator’s
vent-air intake and exhaust pipin
g
.
11. Remove the phillips head screw and retainin
g
washer which secure the vent-air exhaust and
intake flexible vent pipin
g
to the vent terminal
housin
g
. See Fi
g
ure 13.
12. Remove both the intake and exhaust vent pipin
g
from the vent terminal housin
g
.
Care must be
taken not to damage the "O" ring seals when
removing the piping.
13. Remove ri
g
ht dinette assembl
y
cover panel to
access the refri
g
erator retainin
g
bracket. Refer-
ence "Ri
g
ht Dinette Assembl
y
Cover Panel Re-
moval" in the Interior Section.
14. Loosen and remove the refri
g
erator’s retainin
g
screws at rear base of the refri
g
erator.
15. Position the flexible vent-air intake and exhaust
pipin
g
to remove the refri
g
erator from its enclosure.
16. To re-install the refri
g
erator, reverse the removal
procedure.
17. After connectin
g
the vehicle’s
g
as suppl
y
line to
the refri
g
erator’s manual shut-off valve, turn the
valve on. Use a manometer and verif
y
that the
input
g
as pressure is at 11" W.C..
18. Turn off the
g
as suppl
y
at the manual shut-off
valve. Observe the manometer and verif
y
that the
g
as pressure is maintained. If not, locate the
source of the leak, correct it, and re-test the unit.
19. Appl
y
leak test solution to all
g
as fittin
g
s and
verif
y
that there are no leaks.
Do not test for gas
leaks with an open flame.
Intake Pipe
Exhaust Pipe
(
Isolated
)
Retainin
g
Washer
Fi
g
ure 13 - Vent Terminal Housin
g
21