40
SERVICE (cont.)
LAMP STARTER and SOCKET
Location:
The lamp starter (6) is located inside the door assy (1)
on the top of the door lower panel (5).
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the starter leads from the door wiring
harness.
3. Remove lamp starter from starter socket.
4. Check for continuity on each lead of the starter
socket.
If continuity is present as described the starter socket
is operating properly.
If continuity is not present as described replace the
starter socket.
6. Remove starter (6) from starter socket.
7. Check for continuity across the pins on the bottom
of the starter (6).
If continuity is present as described, replace the
starter.
If continuity is not present as described, starter is
operating properly.
Note: If continuity tests are both as described and lamp
does not light, replace the starter.
Removal and Replacement (Refer to Fig. 33):
1. Open dispenser door assy (1)
2. Remove the five #6-32 screws securing the door
lower panel (5) to the door assy (1).
3. Disconnect the leads on the starter socket from the
door wiring harness.
4. Remove lower door panel (5) and starter w/socket
(6) as assembly.
5. Compress the spring tabs on the socket and remove
socket from the door bottom cover (5).
6. Rotate starter 90° and remove from the starter
socket.
7. Insert new starter (6) into socket and turn 90° until
the pins snap in place.
8. Install new socket by compressing spring tabs on
the socket and pushing the socket up through the
hole in the lower door panel (5) and releasing spring
tabs.
9. Connect the sockets leads to the door wiring har-
ness.
10. Install door lower panel (5) with starter and starter
socket on door assy (1) using five #6-32 screws.
42672 122209