Bunn ingle Multi- BrewWISEDBC WITH SMART FUNNELTM Coffeemaker User Manual


 
Page 32
NEW SPRAY FLOW
XX.X MI/M
ENTER MI XX.X
(-) DONE (+)
CALIBRATE FLOW?
NO YES
SPRAYHEAD CAL?
NO YES
CONTAINER RDY?
QUIT YES
CALIBRATE SPRAY
PRESSBREWSTART
CALIBRATE SPRAY
60 SEC TO FINISH
COUNTS DOWN
TO ZERO
AFTER 1 MINUTE
BREW PRESSED
EXIT TO THE
NEXT FUNCTION
SCREEN
P3223
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
CALIBRATE FLOW
This function allows the operator to enter the
actual flow rate of the sprayhead and the dilution by
dispensing both separately for one minute. The vol-
umes are then entered in milliliters per minute. (MI/M)
Procedures to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated in millili-
ters, and with a minimum capacity of 1800 millili-
ters, beneath the funnel on the brewer.
2. Press and hold the ® pad until the display reads
WARMER OFF. Release the ® pad. Press and
release the ® pad until the display reads CALI-
BRATE FLOW.
3. Press and release YES to advance to the SPRAY-
HEAD CAL? function screen. (Pressing NO in the
CALIBRATE FLOW screen will advance to the next
function screen, BREW COUNTERS).
4. Press and release the YES pad. The display should
read CONTAINER READY? If the container is un-
der the funnel, press YES. The display should read
CALIBRATE SPRAY .. PRESS BREW TO START.
5. Press and release the "BREW" pad. The display
should read CALIBRATE SPRAY .. 60 SEC TO
FINISH. The 60 second timer on the display will
count down to zero. When the counter reaches
zero, the display will change to ENTER MI., along
with a number measured in ounces per minute.
6. Measure the amount of water in the container and
using the (-) or (+) pads, adjust the amount on the
display to match the amount in the container. Then
press DONE.
7. The display should now read NEW SPRAY FLOW,
along with the correct flow rate of the sprayhead in
ounces per minute. After about 5 seconds, the
display will return to the CALIBRATE FLOW screen.
8. To exit the CALIBRATE FLOW program, press NO
to advance to the next function screen, or press
the "ON/OFF/LOWER" pad located on the front
switch panel to exit the CALIBRATE FLOW func-
tion and return to the MAIN SCREEN.
37467 110904