Page 13
MAIN SCREEN
READY TO BREW
WATER TEMP: 93°
This screen will be shown when the brewer is
ready for use. The screen displays the water tempera-
ture in the tank. When the water in the tank reaches the
correct set temperature, the display will change from
HEATING to READY TO BREW.
PROGRAMMING LOCKOUT SWITCH (mounted on
main control board)
This switch can be set to prevent access to the
programming levels of the brewer. Once all the correct
brew settings are programmed, the operator can set
the switch to the "DISABLE" position to prohibit any-
one from changing the settings.
BREW LOCKOUT
This function allows the operator to prevent or
allow brewing if the water temperature is less than the
set READY temperature.
To access this function screen press and hold the
® symbol. Release the ® when the display reads:
BREW LOCKOUT?
NO DONE YES
Press here
for NO
Press here
for DONE
Press here
for YES
PROGRAMMING FUNCTIONS - LEVEL 1
The YES or NO should be flashing. Select YES to
prevent brewing if the water temperature is below the
set READY temperature. Select NO to permit brewing
at any water temperature.
When finished, press and release DONE. This will
exit this function screen and return to the MAIN
SCREEN on the display.
PROGRAMMING THE BREWER
The programming of the brewer is divided into two levels. There is one function in Level 1. All other functions
are accessed in Level 2.
The following function screens are in order of appearance. Each screen will have instructions on how to access,
and the procedures to program the various functions of the brewer.
IMPORTANT PROGRAMMING NOTES
- READ CAREFULLY -
To exit the programming mode at any time, press and release the "ON/OFF/LOWER" pad located on the front
switch panel. The display will return to the MAIN SCREEN.
If none of the five programming switches are pressed within one minute during the setup of the brewer, the
programming of the function screen that is being set will be exited and the display will return to the MAIN SCREEN.
Always remember to place a container and funnel under the sprayhead when operating the brewer during the
set-up of PULSE BREW - SET BY EXAMPLE, CALIBRATE FLOW and testing the brew and bypass valves in SERVICE
TOOLS/TEST OUTPUTS.
PROGRAM
ENABLE
DISABLE
PROGRAMMING
SWITCH
P2424