PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
SET PULSE BREW:
This function allows the operator to program the
brewer to "pulse” the sprayhead flow on and off dur-
ing a brew cycle (start and stop the flow of water out
of the sprayhead). This feature allows the ability to
“fine-tune” the brewer for specific flavor profiles. Pulse
brewing can be set up for any and all batches.
a) 1st ON TIME - This time is the duration from when
the "BREW" pad is pressed to when the desired
water level in the funnel is reached. (Soaking the
grounds/tea)
b) OFF-TIME - This time is the duration from when
the water in the funnel reaches the desired ON
TIME level to when it drains out of the funnel to a
desired lower level.
c) LAST ON-TIME- This time is the duration from when
the water in the funnel drains down to the lower
level to when it fills the funnel to a desired higher
level. (Soaking the grounds/tea).
These three times can be set two different ways.
The first is by observing the flow of water for on and
off times. This is accomplished by utilizing the SET
BY EXAMPLE screen and following the subsequent
steps under that function.
The other allows the actual times to be entered
for each of the settings. This is done by utilizing the
ENTER TIMES screen and following the subsequent
steps under that function.
Either of these methods can be used to set the
pulse brew for each batch.
INITIAL SPRAY
INITIAL SPRAY
ALTERNATES UNTIL
BREW CYCLE IS
COMPLETED
PRE-INFUSION
REMAINING ON
ON-
TIME
OFF-
TIME
OFF-TIME
OFF-
TIME
OFF-
TIME
ON-
TIME
ON-
TIME
P2293
Modifying pulse brew:
Range: 1st on time - off to 4 minutes
Off time - off to 4 minutes
Last on time - off to 4 minutes
NOTE: If the brewer is already in the SET PULSE BREW
screen, it is not necessary to follow steps 1 through 8
in this section, but proceed directly to step 9.
1. Press and hold the ® pad until the display reads
WARMER OFF. Release the ® pad. Press the ®
until the display reads REVIEW RECIPES.
2. Press YES to proceed. The display should now
read NO NAME, along with MODIFY and NEXT.
3. Press and release NEXT to advance to the desired
coffee name to be modified.
4. Press and release MODIFY. The display should
read BREW MI/M.
5. Press and release DONE. The display should read
BATCHES DONE?.
6. Press and release YES. The display should now
read % DILUTION.
7. Press and release DONE. The display should read
BATCHES DONE?.
8. Press and release YES. The display should now
read SET PULSE BREW.
9. Press and release YES. The display should now
read SET BY EXAMPLE.
10. If setting Pulse brew BY EXAMPLE (brewing into
a funnel) press YES and proceed with the setup
instructions for
SETTING PULSE BREW - BY EX-
AMPLE,
on page 26.
11. If setting Pulse brew by ENTER TIMES (entering
known times) press NO. The display should read
ENTER TIMES. Press and release YES and pro-
ceed with the setup instructions for
SETTING
PULSE BREW - ENTER TIMES,
page 27.