Bunn ITCB-DV Beverage Dispenser User Manual


 
Page 66
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE REMEDY
Check plumbing and shut-off
valves
Check tank drain clamp
Direction of flow arrow must be
pointing towards direction of water
flow.
Remove the strainer and check for
obstructions. Clear or replace.
Check the sensitivity setting. Refer
to the REFILL function on page
47. If the left three digit number
is less than the right number, the
machine “thinks” it is full and the
refill valve should be off. If the left
number is larger than the right, then
the refill valve will automatically be
turned on to fill the tank. The right
number is the threshold setting and
can be adjusted to compensate for
extreme water conditions: very pure,
low conductance water requires a
higher setting, while high mineral
content, high conductance water
requires a lower setting. Note that
the left number changes from a high
value when water is NOT touching
the refill probe to a low valve when
water IS touching the probe. For best
operation, the right number should
be set to a value midway between
these low and high numbers. Be-
fore changing the setting, confirm
that the refill probe is free of scale
buildup and the connection to it is
Automatic refill will not operate
or display shows FILL TIME TOO
LONG
1. No water
2. Tank drain clamp
3. Water Strainer
4. Refill probe or Sensitivity set-
ting
5. Refill valve
36748 080904