Bunn ITCB-DV Beverage Dispenser User Manual


 
Page 68
TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
Water flows into tank continuously
with power removed from brewer.
1. Refill valve
2. Refill probe or sensitivity set-
ting
3. Control Board
Foreign material lodged in valve,
holding it in open state.
Check the sensitivity setting. Refer
to the REFILL function on page
47. If the left three digit number
is less than the right number, the
machine “thinks” it is full and the
refill valve should be off. If the left
number is larger than the right, then
the refill valve will automatically be
turned on to fill the tank. The right
number is the threshold setting and
can be adjusted to compensate for
extreme water conditions: very pure,
low conductance water requires a
higher setting, while high mineral
content, high conductance water
requires a lower setting. Note that
the left number changes from a high
value when water is NOT touching
the refill probe to a low valve when
water IS touching the probe. For
best operation, the right number
should be set to a value midway
between these low and high num-
bers. Before changing the setting,
confirm that the refill probe is free
of scale buildup and the connection
to it is secure.
Substitute a control board known
to be in good working order.
36748 041504