Bunn SRU Coffeemaker User Manual


 
Page 31
SERVICE (cont.)
TIMER (Early Models)(cont.)
To Three Pin Female
Connector on Main
Harness
BLK to Pump Lead
WHI to Pump Lead
Three Pin Connector from
Half/Full Batch Switch
FIG. 28 TIMER TERMINALS
P1751
10067 080200
Removal and Replacement:
1. Separate all connectors between the brewer wir-
ing harness and the timer.
2. Disconnect the timer leads from the pump leads.
3. Remove the two #8-32 screws securing the brew
timer to the component bracket and remove timer.
4. Install new timer circuit board as described in
Late
Model Timer
section on the following pages.
5. Refer to Fig. 30 to reconnect the wires.
6. Install the Timer Setting Decal, provided with the
timer replacement kit, on the back of the front
access panel.
7. Adjust the timer as required. Refer to
Late Model
Timer
section on the following pages.